Fume hood is fabricated from special grade pre coated mild steel sheet duly powder coated from outside and epoxy painted from inside. The Inner wall of chamber is covered with epoxy coated FRP lining which duly provides better protection from acid fumes in the Lab.

Double wall feature provides easy access to utilities like water, gas, vacuum & electricity. Detachable base storage cabinets are provided with castors for easy maintenance. High performance centrifugal blower is provided with different ducting material.

    Fume Hood SSGW Manufacturers

    The fume hood is made of special grade pre-coated mild steel sheet that has been powder coated on the exterior and epoxy painted on the inside. The inner wall of the chamber is lined with epoxy coated FRP, which provides superior protection from acid fumes in the laboratory. We provide best Fume Hood SSGW lab space hood get online order from Fume Hood SSGW manufacturers experts.

    Baffle:

    Removable plates integrated into the work chamber’s rear or top to provide a plenum between the work chamber and the exhaust duct connection to promote uniform fume scavenging and the point of release.

    System of Exhaust:

    All exhaust air ducting, fans, and related equipment installed at the point of connection to the fume hood and discharge.

    Face Acceleration:

    The velocity of the air going through the fume hood’s work opening measured in the plane of the sash. Feet per minute (fpm) or litres per second (lps)

    Fume Hood SSGW Airbrush Makeup

    The amount of air required to replace the air expelled from a room by the fume hood and other ventilation systems.

    Plenum:

    A low-velocity chamber that is used to spread static pressure (from the system’s fan) across its interior.

    Sash: A transparent safety screen in the fume hood’s work opening that can be placed between the operator and the work chamber for protection. The entrance may be adjusted vertically to change the size and control the face velocity of air entering the fume hood.

    Sash Aperture: The size of the opening in the sash movement direction.

    Noise Level: When measured 6″ in front of the sash, the noise emitted by the smoke does not exceed 60dBA on the A scale.

    Electrical: All electrical fittings are pre-wired to a junction box on the ceiling of the bench Top fume hood superstructure and are factory installed. The working table is composed of acid-resistant glazed tiles and is outfitted with gas/air petcocks, additional power outlets, and light lamps.

    230V, 50/60Hz voltage